HOME MANAGEMENT PRODUCT NEWS BUILDERS FAQ's

The Tried and Proven Line Of Products

The fact of the matter is, the No-Burn®line of products are ICC (International Code Council) approved (AC 363) which means that they have passed a very demanding and difficult criteria (ESR 1838). They have passed the NFPA (National Fire Protection Association) room test 286 and the ASTM E-84 (American Standards for Testing and Materials) and the NFPA 255, 701, the ASTM E-119 2 hour Wood stud wall barrier test which falls under the NFPA 703 Criteria, the UL 723, ULC and the ASTM D-5590 zero mold growth on the MIH products. Not to mention, that on an FRCR (Fire Resistive Class Rating) -1application, you get a One Million dollar product liability coverage policy. As a homeowner, it can save up to 30% on your homeowners insurance policy. As a builder, it can save up to 30% on your builders risk. Now what other Fire retardant protective product can say all that? More importantly is that the flame spread and the smoke development on the ASTM E-84 test was 5 flame spread and 25 smoke development. That's incredible, and its all about saving lives!

PLUS PRODUCTS

NO-BURN® PLUS

In most structures, the interior walls that cover the framing are the first line of defence against a fire, weakening the structural integrity of a building. To aid in this defense, NO-BURN® PLUS was developed. NO-BURN® PLUS is an interior latex paint product that can be used as a base or primer or tinted to match the finish coat. NO-BURN® PLUS is an intumescent fire reactant that when introduced to heat or flame, foams up providing a protective char barrier that shields the underlying materials from heat and fire. This protective barrier "swells", creating an intact "cocoon" that can withstand a tremendous amount of heat and fire.

In new construction, NO-BURN® PLUS works very well as a primer coat, applied directly to new drywall or wood. NO-BURN® PLUS provides a solid, bright white surface for the application of finish coats. In existing homes and businesses, NO-BURN® PLUS can be tinted and used as a finish coat for those who want the protection applied as a final coat. NO-BURN® PLUS can also be used on the framing of a structure, giving the entire structure a Class A rating on all the structural components. Having a Class A rating gives the structure the best possible protection against fire, especially in areas where a high fire hazard exists such as urban areas with homes in close proximity, or in woodland areas.

USES: NO-BURN® PLUS can be applied just like any latex paint and can be used on wood, drywall, plastic; anywhere regular latex paint can be used. It must be applied by a certified NO-BURN® TECHNOLOGY INC. applicator.

NO-BURN® PLUS Mih

In resent years, the nation has been gripped by the fear that their own home is making them sick, well-known as " sick home syndrome". Because homes and businesses are being built "tighter", moisture that is trapped within the walls before, during or after construction, is contributing to the growth of toxic mold, often referred to as "black mold". This mold travels through the air and is inhaled by the occupants causing a multitude of health problems. The problem of black mold has been labeled the "next asbestos" by many experts. Lawsuits are springing up all over the country because of the severity of the problem. To help Contractors, developers and homeowners with this problem, NO-BURN®, INC. developed NO-BURN® PLUS Mih.

NO-BURN® PLUS SYSTEM FOR OUTDOOR USE

The NO-BURN® PLUS SYSTEM FOR OUTDOOR USE was specifically developed in response to the wildfire problems in the United states, as well as the prevalence of wooden structures in close proximity in neighborhoods across the U.S. and around the world. The PLUS SYSTEM FOR OUTDOOR USE consists of the application of two coats of NO-BURN® PLUS painted on the exterior surfaces, then sealed with a top coat of a high quality exterior paint.

USES: For exterior wood surfaces and surfaces under aluminum siding, brick veneer, and other protective surfaces.

WOOD GARD PRODUCTS

NO-BURN® WOOD GARD

Wood is the primary component used in the construction of most houses and many commercial facilities. These structures, especially during the framing stage, are very susceptible to fire. Once the structure is completed, the wood dries out over time leaving a very volatile mass of fuel to burn. Whether the fire is started by human error, an electrical malfunction, lightning, chimney fire or other means of ignition, if the structure is not protected, it will burn. With lightweight building materials and construction methods in use today, many of these homes and businesses are experiencing structural failure within minutes of a fire starting. This leads to injury and death of both occupants and firefighters.

NO-BURN® WOOD GARD is the answer! When applied during the framing of the structure, NO-BURN® WOOD GARD protects indefinitely. Whether an electrical short inside a wall, the structure sustains a lightning strike or a fire within the living space extends to the framing, NO-BURN® WOOD GARD is ready to protect the structure. As time passes and wood dries out, WOOD GARD remains intact ready to do its job. NO-BURN® WOOD GARD is a Class A fire reactant that encapsulates the wood itself and protects it by retarding fire.

USES: Use on wood framing during the framing stage of construction. Use on "hot spots" in your home: around dryer vents, electrical boxes, furnaces, fireplaces, in attics and garages.

NO-BURN® WOOD GARD Mih

NO-BURN® WOOD GARD Mih is a dual action product that has proven to be effective against the potential of fires as a Class A fire reactant and also inhibits the growth of toxic black mold (stachybotrus chartarum), according to ASTM D5590-94. The product has proven to be more effective with regards to the preservation of the structural integrity of wooden structures when tested against FRT plywood and impregnated wood, both particularly when subjected to repeated exposures to flames and fire.

ORIGINAL

NO-BURN® ORIGINAL

NO-BURN® ORIGINAL is a versatile product that can be used to achieve NO-BURN's fire-inhibiting capabilities on wood furniture, mantels, banisters, cabinets, crafts, various hobbies and wood (prior to finishing) i.e. ornamental surfaces, as well as wood shake roofs. ORIGINAL does not leave a residue.

USES: Use on wood shake roofs, wood furniture, crafts, mantels, banisters, kitchen cabinets, ornamental wood (before finishing-sealing).

FABRIC FIRE GARD

NO-BURN® FABRIC FIRE GARD

Interior furnishings are the number one contributing factor to the swift spread of fire and smoke within a home. In most cases, it is the toxic smoke that kills the occupants, not the fire itself. Interior furnishings also contribute to the phenomenon know as "flashover", in which the air within a structure becomes superheated, causing everything within the vicinity of the fire to explode into flames. It is not survivable by occupants, and rarely by fully protected firefighters. FABRIC FIRE GARD, a clear and odorless liquid, was developed to help alleviate this problem. Not only can FABRIC FIRE GARD slow down the fire, but in many cases it will not allow interior furnishings to catch fire.

USES: Use FABRIC FIRE GARD on upholstery, bedding and mattresses, drapes, curtains, furnishings, tablecloths, pot holders, stuffed toys, crafts, clothing, holiday decorations, costumes and many other household items etc. NOT FOR USE ON LEATHER.

FABRIC FIRE GARD is available in quantities of 1 gallon, 5 gallons and 55 gallons.

 

©COPYRIGHT2007 NO-BURN®TECHNOLOGY©BUBBAS WEB DESIGN®